A-38 HS-21/HS-41X Handheld Reader User’s Manual
Serial Commands
85 Trioptic Options 0
Binary Dip Switch
86 Motion Detection: Event 3
Valid Range: (see register 39)
Motion detection is enabled by setting
register C4 to 0xF0.
This register is reset to 0 (disabled)
when register C4 is changed away
from 0xF0.
When motion is detected, this event is
posted.
See register 39 for list of events.
Also see registers: 20E
87 Motion Sensitivity 5
Valid Range: 0 to FFFF (#65535) ms
Also see registers: 86, 20E
93 Suppress Beep On Decode 0
0: Beep indicating decode before
JavaScript processing
1: Call JavaScript without beeping to
indicate decode
Normally, the Reader beeps as soon as
decodes are read and processes them
via JavaScript if necessary after the
beep. To enable JavaScript to control
the beep feedback, change this setting
to 1; this will suppress the beep; the
JavaScript would typically beep if the
decode is valid or start another read
cycle if it isn’t.
This setting does not suppress beeps
for anything but a successful decode
event.
98 Decoder HD field (FOI0) X Offset 0
Valid Range: 0 to 639 pixels
Decoder uses the pixels after the specified
pixel offset in the HD field (FOI0).
Also see registers: 53, 54, 99
Bit Controls Value
0
Trioptic Decoding,
Normal Quiet Zones
0: Disabled
1: Enabled
1
Allow Short Quiet
Zones
0: Disabled
1: Enabled
2
No Quiet Zones
(requires firmware
version 3280+)
0: Disabled
1: Enabled