A-44 HS-21/HS-41X Handheld Reader User’s Manual
Serial Commands
1DC Pharmacode Settings 28A40
Binary Dip Switch
1EA Good Read Duration (ms) C8 (#200)
Valid Range: 0 to 7FFFFFF Milliseconds
1EB Decoder Data Matrix Module Size 32 (#50)
20E Motion Detection: Start Delay (ms) 0
Valid Range: 0 to 7FFFFFFF Millisec-
onds
A built-in delay of 200 ms prevents
motion detect to detect motion right
after a successful decode. This allows
the bar code to be removed without
triggering a new decode. Use this to
add an additional delay amount.
Also see register: 86
Bit Controls Value
0
Direction
0: Forward
1: Reverse
1
Fixed Symbol
Length Status
0: Disabled
1: Enabled
3-2
Bar Width Status
0 = Mixed
1 = All Narrow
2 = All Wide
3 = Use
Fixed
Threshold
8-4
Minimum Number of
Bars Value
4-10 (#16)
(Default 4)
13-9
Fixed Symbol
Length Value
1-10 (16)
(Default 5)
29-
14
Fixed Bar Width
Threshold
0-FFFF
(#65535)
(Default 10)