Microscan MS-2 Instrukcja Użytkownika Strona 50

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 125
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 49
4-4 MS-2 CCD Reader User’s Manual
MS-2 Read Cycle Overview
MS-2 Read Cycle Overview
The MS-2 outputs symbol data as soon as it is decoded. There is no “End of Read Cycle”
option. Multiple symbol operations are emulated by controlling the read cycle duration
and the time allowed between identical consecutive decodes.
The following conditions also apply:
1. In Single symbol mode, a read cycle ends only on a decode, falling trigger, or timeout.
2. In Multiple symbol mode, the read cycle begins on a triggered event, but starts over
after any symbol has been decoded.
3. There is no “new trigger” feature.
4. There is no timeout for External Level mode.
5. There is no Continuous Read 1 Output setting in Trigger Mode, but this setting can
be emulated by following the steps described in
Continuous Read 1 Output Emulation
.
Przeglądanie stron 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 124 125

Komentarze do niniejszej Instrukcji

Brak uwag