8-4
EZ Match User Manual
I/O Parameters Serial Commands
ISO/IEC 16022 Symbol Quality Output 2
<K801,output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity,
axial non-uniformity threshold,output on unused ECC,unused ECC
threshold>
ISO/IEC 16022 Symbol Quality Output 3
<K802,output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity,
axial non-uniformity threshold,output on unused ECC,unused ECC
threshold>
Configurable Output 1 <K810,output on,output state,pulse width,output mode>
Configurable Output 2 <K811,output on,output state,pulse width,output mode>
Configurable Output 3 <K812,output on,output state,pulse width,output mode>
Tube/Cap Detection Output 1 <K860,mode,output on>
Tube/Cap Detection Output 2 <K861,mode,output on>
Tube/Cap Detection Output 3 <K862,mode,output on>