MS-4Xi Imager User Manual
5-21
Read Cycle
Capture Timing
Note: Capture Timing applies only to Rapid Capture Mode.
Time Before First Capture
Usage: In almost any moving line application, a time delay is needed to ensure that
a symbol will be in the imager’s field of view at the beginning of the capture
sequence.
Definition: Time Before First Capture in a moving line application is the time between
an external trigger event and the occurrence of the first capture.
Serial Cmd: <K242,time before 1st capture,time between capture 1 and capture
2,,,,,,,,time between capture 7 and capture 8>
Default: 0
Options: 0 to 65535 (2.097 seconds, in 32
µS increments)
Start of
Read Cycle
Time Before First Capture
Processing