MS-4Xi Imager User Manual
Output Filter Configuration
Data
Database Index
Definition:
This is the data string to be used when comparing symbol data for output filtering
and ordering. This data string may also contain wildcard and placeholder
characters to facilitate matching. Remember that in order to filter or order
symbol data, it must meet all the requirements of the selected filter index.
Examples:
Filter data = “123*”. This will match data strings of “123”, “123456”, a
nd
“1
23ABC”, but not “12”.
Filter data = “123*AB?C”. This will be interpreted as “123*”.
Filter data = “123?”. This will match “1234” and “123A”, but not “123”,
12345”, or “1234C”.
Filter data = “123?A”. This will match “1234A” and
“123BA”, but not
123”, “1234C”, or “1234ABCD”.
Filter data = “123?A?”. This will match “1234AB” and “123BAT
”, but not
“1234A” or “123BATS”.
Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”,
bu
t not “12” or “123”.
Filter data = “123?A*”. This will match “1234A”,
“123BA”, and
123BATS”, but not “1234” or “1234C”.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>
Default: 00 (NUL)
Options: Any ASCII input in the form of a pair of hex characters.
Maximum length: 63 bytes defined.
Examples:
41422A = AB*
Data [0] = NUL represents string matching disabled.
Definition: The index of the database entry that decodes a given symbol must equal this
setting for filtering to occur. A setting of 0 allows any database index for this
filter entry.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>
Default: 0 (any index)
Options: 0 to 10