Chapter 8 I/0 Parameters
MS-9 Scanner User’s Manual 8-7
Beeper
Beeper Status
Usage: Can be used as an audible verification that either a good read or a noread
has occurred.
Definition: A beep is emitted either after each good read of a bar code symbol or
after each noread.
Note: Beeper will also sound if any of the following occur:
the scanner is defaulted
•a send/save command from ESP or an Exit command from any
embedded menu
•a <Z>, <Zp>, <Zd>, or <KS,1> command is sent
Serial Cmd: <K702,status,volume>
Default: On Good
Options: 0 = Disabled
1 = On Good Read
2 = On Noread