Przeglądanie stron 171
Master Database
12-14 MS-9 Scanner User’s Manual
Request Master Symbol Data
Definition: Returns master symbol data for any enabled master symbols from 1 to 10.
For example, for a database in which the master symbol database size
has been set to 5 or more, send <M5?> to request master symbol data
for #5. The scanner transmits master symbol #5 data in the following
format: <5/data>.
If no master symbol data is available, the output will be: <5/>.
ESP: 1. Click the Utilities button and the Master Database tab.
2. Click on the Receive Scanner’s Database button.
Serial Cmd: <Mmaster symbol number?> (Returns all master symbols if no num-
ber is added before the question mark)
Caution: Be sure to add the ? or you will delete the master symbol(s).
Default: Returns all master symbols if no number is included.
Options: 1 to 10