Microscan MS-96 Instrukcja Użytkownika Strona 128

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 226
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 127
Output 1 Parameters
8-12 MS-9 Scanner User’s Manual
Active State
Pulse Width
Definition: Sets the active state of the discrete output.
Serial Cmd: <K810,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,decodes per trig-
ger>
Default: Normally Open
Options: 0 = Normally Open 1 = Normally Closed
Definition: Sets the time in 10 mS increments that the discrete output remains active.
Serial Cmd: <K810,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,decodes per trig-
ger>
Default: 5 (.05 seconds). Corresponds to 50 mS displayed in the menu.
Options: 1 to 255 (0.01 to 2.55 seconds). Divide the number entered on the com-
mand line by 100 for time in seconds.
Przeglądanie stron 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 225 226

Komentarze do niniejszej Instrukcji

Brak uwag