Bar Code Output
8-10 MS-820 Industrial Bar Code Scanner User’s Manual
8–Outputs
End of Read Cycle
Definition: Enabling End of Read Cycle means that bar code data does not get
sent to the host until the read cycle ends with a timeout or new trigger.
Usage: End of Read Cycle is useful in timing-based systems in which the host
is not ready to accept data at the time it is decoded.
Read cycle Duration
Start of read cycle
End of read cycle
This is when host
expects output
Host
activates trigger
Figure 8-2 Read Cycle