Chapter 10 Diagnostics
MS-820 Industrial Bar Code Scanner User’s Manual 10-5
10–Diagnostics
Laser High Warning
Transmits a message whenever the laser current exceeds a factory-calibrated refer-
ence value which cannot be altered. The message repeats once every 30 minutes until
the condition is corrected.
Laser High Status
Laser High Message
Definition: Enables the Laser High message.
Usage: Alerts the user to impending laser failure. (Contact Microscan Service.)
Serial Cmd: <K”warning message status,laser high status,laser low status,
novram/reset warning status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Defines the Laser High message.
Serial Cmd: <K;laser high message>
Default: HI-LASER
Options: Any 1 to 10 character ASCII string except NUL, <, or >.