Microscan MS-820 Instrukcja Użytkownika Strona 152

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 222
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 151
Warning Messages
10-6 MS-820 Industrial Bar Code Scanner User’s Manual
10–Diagnostics
Laser Low Warning
When enabled a message up to 10-characters is transmitted whenever the laser cur-
rent falls below a factory-calibrated reference value which cannot be altered. The
message repeats once every 30 minutes until the condition is corrected.
Laser Low Status
Laser Low Message
Definition: Enables the Laser Low message.
Usage: Alerts the user to impending laser failure. (Contact Microscan Service.)
Serial Cmd: <K”warning message status,laser high status,laser low status,
novram/reset warning status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: When enabled a message up to 10-characters is transmitted whenever
the laser current falls below a factory-calibrated reference value which
cannot be altered. The message repeats once every 30 minutes until
the condition is corrected.
Defines the Laser Low message.
Serial Cmd: <K:laser low message>
Default: LO-LASER
Options: Any 1 to 10 character ASCII string except NUL, <, or >.