Microscan MS-4X Instrukcja Użytkownika Strona 117

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 374
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 116
MS-4X Imager User Manual
5-21
Read Cycle
Capture Timing
Note: Capture Timing applies only to Rapid Capture Mode.
Time Before First Capture
Usage: In almost any moving line application, a time delay is needed to ensure that
a symbol will be in the imager’s field of view at the beginning of the capture
sequence.
Definition: Time Before First Capture in a moving line application is the time between
an external trigger event and the occurrence of the first capture.
Serial Cmd: <K242,time before 1st capture,time between capture 1 and capture
2,,,,,,,,time between capture 7 and capture 8>
Default: 0
Options: 0 to 65535 (2.097 seconds, in 32
µS increments)
Start of
Read Cycle
Time Before First Capture
Processing
Przeglądanie stron 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 373 374

Komentarze do niniejszej Instrukcji

Vikitpm 04 Jan 2024 | 14:20:38

urenrjrjkvnm

Evapsi 06 Jan 2024 | 23:41:38

Med