MS-4X Imager User Manual
10-11
Camera and IP Setup
Window of Interest by Serial Command
The figure shows where to locate the start
position of the row and column pointers and
how to measure the column depth and row
width dimensions.
Top (Row Pointer)
Left (Column Pointer)
Important: The column pointer setting must be an even value.
Height (Row Depth)
Width (Column Width)
Definition: Defines the row position of the
upper-left starting point of the
window.
Serial
Cmd:
<K516,row pointer,column
pointer,row depth,column width>
Default: 0
Options: 0 to 480
Definition: Defines the column position of the upper-left starting point of the window.
Serial Cmd: <K516,row pointer,column pointer,row depth,column width>
Default: 0
Options: 0 to 640
Definition: Defines the size, in rows, of the window. Maximum value is defined
as the maximum row size of the image sensor minus the Top value.
Serial Cmd: <K516,row pointer,column pointer,row depth,column width>
Default: 0
Options: 3 to (480 - row pointer)
Definition: Defines the column position of the upper-left starting point of the
window.
Serial Cmd: <K516,row pointer,column pointer,row depth,column width>
Default: 0
Options: 8 to (640 - column pointer)
WOI Column
Pointer
WOI Row Pointer
WOI Column Width
WOI Row Depth