Microscan MS-4X Instrukcja Użytkownika Strona 262

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 374
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 261
10-22
MS-4X Imager Us
er Manual
Illumination Brightness
Illumination Brightness
Constant
When set to Constant, the illumination is the same as the Medium setting. However, the
LEDs will always be on during a read cycle and will only be off between read cycles. This
cuts down on perceptible LED flashing.
Definition: This feature allows the user to adjust the brightness of the illumination
LEDs. Since the imager has control over the brightness of the illumination,
it can provide consistent brightness output between imagers through a
factory calibration operation. Each of the brightness settings is calibrated
to provide the same level of intensity for each imager.
Serial Cmd: <K536,brightness>
Default: High
Options: 0 = Off
1 = Low
2 = Medium
3 = High
4 = Constant