Load Current Settings from Configuration Database
Load Current Settings from Configuration Database
Example:
<K255-,5>
This command phrase loads the configuration settings contained in database index 5 to
current, active configuration settings.
Load Current Settings from Configuration Database by ESP
Notes on Symbol Type
•The current DataBar Expanded status does not change if it is configured as Enabled
(Stacked) and the database DataBar Expanded status is Enabled.
•The current DataBar-14 status does not change if it is configured as Enabled (Sta
cked)
and the d
atabase DataBar Expanded status is Enabled.
Data Matrix ECC level is determined by the
current
settings and not by
database
settings
.
Th
erefore, the database does not know which ECC level to enable,
and has no effect on
cu
rrent Data Matrix ECC settings
.
Definition: Allows the configuration settings contained in a selected database index to
be loaded to current, active configuration settings.
Serial Cmd: <K255-,index>
Click the Load Index to
Current button to load
configuration settings
from the selected index
to current, active settings.