Microscan Quadrus EZ Instrukcja Użytkownika Strona 127

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 366
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 126
Quadrus EZ Reader User’s Manual 5-11
I/O Parameters
Minimum Number of Qualified Scan Lines
Start/Stop Status
Definition:
Sets the minimum number of scans that have the required number of bars
set in Minimum Number of Bars.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified
scans,start and stop status>
Default: 0
Options: 0 to 11 (0 is disabled)
Definition:
When enabled, both Start and Stop characters need to be present to qual-
ify as a decodable symbol. In the case of PDF417, only a Stop or Stop
needs to be present.
Note: This parameter does not apply to UPC, Pharmacode, RSS and Micro
PDF417.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified scans,start
and stop status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Przeglądanie stron 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 365 366

Komentarze do niniejszej Instrukcji

Brak uwag