Quadrus EZ Reader User’s Manual 5-15
I/O Parameters
Dimension 2 (2D Symbology Qualification)
Dimension Tolerance (2D Symbology Qualification)
Definition:
Checks symbol dimension for a specified number of pixels. In the case of
rectangular symbols, checks the shorter side.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimen-
sion tolerance,orientation mode,orientation value>
Default: 0
Options: 0 to 656 pixels
Definition:
Sets the allowable deviation, in percentage, for symbol sizes specified in
Dimension 1 or Dimension 1.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimen-
sion tolerance,orientation mode,orientation value>
Default: 10
Options: 0 to 100