
Quadrus EZ Reader User’s Manual 3-7
Read Cycle
Trigger
Note
: When doing calibration or read rate testing, the current trigger setting will be disregarded
.
Trigger Mode
Continuous Read
Definition: The type of trigger event that will initiate the read cycle.
Serial Cmd: <K200,trigger mode,trigger filter duration>
Default: External Edge
Options:
0 = Continuous Read 1 = Continuous Read 1 Output
2 = External Level 3 = External Edge
4 = Serial Data 5 = Serial Data & External Edge
Usage:
Continuous Read
is useful in testing symbol readability or reader functions.
It is not recommended for normal operations.
Definition:
In Continuous Read, trigger input options are disabled, the reader is
always in the read cycle, and it will attempt to decode and transmit every
capture.
When To Output and Noread options have no affect on Continuous
Read.
Serial Cmd: <K200,0>
Komentarze do niniejszej Instrukcji