Quadrus EZ Reader User’s Manual 6-9
Symbol Quality
Pixels per Element
ECC Level
Matrix Size
Quiet Zone
Definition:
The number of pixels for each element, either dark or light for both x and y
directions.
If enabled, is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode
time,pixels per element,ecc level,matrix size,quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition:
Outputs the ECC type symbology.
If enabled, is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode
time,pixels per element,ecc level,matrix size,quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition:
Defines the symbol matrix size, in number of pixels in both the x and y axis.
If enabled, is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode
time,pixels per element,ecc level,matrix size,quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition:
If enabled, the size of the quiet zone is evaluated and a PASS or FAIL
message is appended to the symbol.
Serial Cmd:
<K710,percent cell damage,total read time,capture time,locate time,decode
time,pixels per element,ecc level,matrix size,quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled