Microscan MINI Hawk Xi Instrukcja Użytkownika Strona 176

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 388
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 175
7-22
MINI Hawk Xi High Performance Imager User Manual
Configurable Output 1
Trend Analysis
Symbol Quality
Diagnostic Warning
In Read Cycle
Usage: Typically used when successful decodes are occurring but a discrete output
is needed to flag a trend in quality issues.
Definition: Activates discrete output when a trend analysis condition is met, depending
on the trend analysis option enabled.
Usage: Typically used when a discrete indication is needed to flag a symbol quality
condition.
Definition: Activates discrete output when a symbol quality condition is met, depending
on the symbol quality option enabled.
Usage: Typically used when a discrete indication of a diagnostic condition is
needed.
Definition: Activates discrete output when a diagnostic warning condition is met,
depending on the diagnostic option enabled.
Definition: Activates a discrete output when the imager is in a read cycle.