MINI Hawk Xi High Performance Imager Us
er Manual 4-13
Calibration
Initiating Calibration
Calibration can be initiated by serial command, the EZ button, or from the Calibration
interface in
ESP
. A symbol must be in the imager’s field of view during the calibration process.
In ESP, the Calibrate button starts the calibration routine.
To initiate calibration by serial command, enter the serial command
<@CAL>
from a terminal,
such as
ESP
’s
Terminal
interface.
<@CAL>
is a calibration routine that emphasizes contrast
and readability.
See Calibrate by EZ Button for the EZ button calibration procedure.