7-30
MINI Hawk Xi High Performance Imager User Manual
Diagnostics Output 1
Diagnostics Output 1
Note: Output On under Output 1 Parameters must be set to Diagnostic Warning for
this output to function.
Under Output 1 Parameters, expand the Diagnostics tree.
Service Unit
When Diagnostic Warning is enabled, the Output On configuration has no effect. The
output will remain active as long as one of the diagnostic warning conditions is met. The
output will become inactive once it detects that there are no diagnostic warning conditions.
Serial Cmd: <K790,unused 1,service unit>
Default: 0
Options: 0 = Disabled
Definition: Allows the user to set up the output to toggle to active when the service
timer has expired. This condition will only be held for one service timer
click.
Note: This feature cannot be used if the imager is in a Continuous Read
mode.
Serial Cmd: <K790,unused 1,service unit>
Default: 0
Options: 0 = Disabled 1 = Enabled