MINI Hawk Xi High Performance Imager Us
er Manual 8-15
Symbol Quality
Quiet Zone (Data Matrix Only)
Symbol Angle (Data Matrix Only)
Definition: When this feature is enabled, the size of the quiet zone is evaluated and
a PASS or FAIL message is appended to the symbol data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: When this feature is enabled, the symbol orientation is appended to
data output as a degree value representing the angle of the Data Matrix
symbol’s L-shaped finder pattern relative to the imager.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled