Chapter 6 Matchcode
MS-3 Laser Scanner User’s Manual 6-13
6–Matchcode
Delete Master Symbol Data
Store Next Symbol Scanned as Master Symbol
Definition: Delete Master Symbol Data allows you to delete an enabled master
symbol.
Serial Cmd: Send <K231,master symbol number,> to delete the master symbol.
Options: 1 to 10
Definition: After you’ve set the size in the database, you can order the scanner to
scan-in the next symbol as the master symbol for any given master
symbol number.
Serial Cmd: <Gmaster symbol number>
To store the next symbol scanned as master symbol #1 send: <G> or
<G1>. For all symbols numbers except 1, the number must be
included.
Options: 1 to 10