Autodiscriminate
5-4 MS-3 Laser Scanner User’s Manual
5–Symbology
Autodiscriminate
Although Autodiscriminate is not a configuration command, but it is included here
as a convenient tool for enabling most symbol types.
Note: If using an I 2/5 symbol, verify that the number of characters in the symbol being
scanned matches the symbol length enabled for the I 2/5 symbol type (default is 10 and 6).
Definition: Enables all available symbology types except PDF417, UCC/EAN 128.
The user may also individually disable/enable each symbology type.
Usage: Commonly used for quick setup mode to detect symbol type. This is
particularly useful for users who might be unfamiliar with their applica-
tion’s symbology.
Note: It does not alter individual fields such as Start/Stop, Fixed
Length, etc. These need to be setup individually.
Serial Cmd: <P>
Default: Code 39 (only)
Options: <P> Enables all codes except noted above.
<Q> Enable Code 39 only
<R> Enable Codabar only
<S> Enable I 2/5 only