Microscan MS-4 Dokumentacja Strona 127

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 202
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 126
Chapter 8 Data Outputs
MS-3 Laser Scanner User’s Manual 8-5
8–Data Outputs
Mismatch
Good Read
When to Output Symbol Data
Usage: Match is used in an application that requires specific symbol informa-
tion and needs to sort, route or verify based on matching the specific
symbol data.
Definition: With Mismatch enabled, the scanner transmits symbol data whenever
the symbol data information does NOT match the master symbol.
Note: A noread can still be transmitted if enabled.
Usage: Mismatch is typically used as a flag within the host system to prevent
an item from being routed in the wrong container.
Definition: With Good Read enabled, the scanner transmits symbol data on any
good read regardless of Matchcode Type setting.
Note: A noread can still be transmitted if enabled.
Usage: Good Read is used when an application requires all symbol data to be
transmitted. It’s typically used in tracking applications in which each
object is uniquely identified.
Definition: This command allows the user to choose when symbol data can be sent
to the host.
Serial Cmd: <K705,symbol output status,when to output>
Default: As Soon As Possible
Options: 0 = As Soon As Possible 1 = End of Read Cycle
Przeglądanie stron 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 201 202

Komentarze do niniejszej Instrukcji

Brak uwag