Microscan MS-4 Dokumentacja Strona 31

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 202
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 30
Chapter 2 Communications
MS-3 Laser Scanner User’s Manual 2-11
2–Communications
Conditions: The conditions for a daisy chain application are as follows:
1. The master scanners trigger must be Serial or
External; the slave scanners’ triggers are con-
figured for Serial.
2. All scanners are enabled to Daisy Chain mode.
3. Each scanner’s auxiliary port must be connected
to the Host port of its slave scanner.
4. Each slave scanner in the daisy chain must be set
to send its data no less than 20mS before its preceding scanner.
5. All but the master scanner must have Postamble enabled and set
to CR (^M) only.
6. All but the master scanner must have their noread messages disabled.
7. If Multisymbol is enabled, Multisymbol Separator characters
must match in all scanners and Number of Symbols must be set
to number large enough to include all the symbols it may itself read
plus the number of symbols that it will be expected to relay to the
host or the next scanner up the line.
8. Symbology ID enable/disable must be the same in all scanners.
9. All but the master scanner must have their diagnostic warning mes-
sages disabled.
10. Daisy Chain ID Status enable/disable and the number of charac-
ters in Daisy Chain ID must be the same in all scanners.
Master