Chapter 4 Read Cycle/Trigger
MS-3 Laser Scanner User’s Manual 4-9
4–Read Cycle/Trig-
Trigger Filter Duration
Definition: Trigger Filter Duration can prevent trigger bounce from falsely trig-
gering the scanner by limiting the time in which trigger pulses can be
received.
Usage: Trigger Filter Duration is useful where trigger bounce could cause
false triggers.
Serial Cmd: <K200,trigger mode,trigger filter duration>
Default: 244(10mS)
Options: 2 to 65535 (corresponding to 82µS to 2.68S in 40.9µS steps)