7-14 QX Hawk Industrial Imager User Manual
Master Database
Request Master Symbol Data
Returns master symbol data for any enabled master symbols from 1 to 10.
1. Click the Utilities button and the Master Database tab.
2. Click the Receive Readers Database button.
Store Next Decoded Symbol to Database Index 1
After the size of the database is set, the imager can read the next symbol as the master
symbol for any given master symbol number.
<Gmaster symbol number>
To store the next symbol decoded as master symbol # 1, send:
<G>.
Store Next Decoded Symbol to Database Index n
To store the next symbol decoded as the master symbol for any other master symbol
database number, send:
<Gmaster symbol number [1-10]>.
For example, <G5> will cause the next symbol read to be entered as master symbol # 5.
In the Master Database tab,
1. Select the master symbol index number in which new symbol data will be stored.
2. Click the Read Symbol into Selected Index button.
Caution: If an index with existing data is selected, that data will be overwritten by the
new decoded data when this command is used.