QX Hawk Industrial Imager User Manual A-127
Appendices
Testing Communications
Using Controller Tags
• Open the Controller Tags dialog and select the Monitor Tags tab at the bottom. Then
expand the output array. The trigger bit is the first bit of the 5th byte offset which is
data[4].0. Setting this bit to 1 should trigger a read on the camera.
•