QX Hawk Industrial Imager User Manual A-65
Appendices
Wild Card Character (Matchcode)
Sequence on No Read (Matchcode)
Sequence on Mismatch (Matchcode)
Master Symbol Database Size
New Master Pin
Master Symbol
Index (Master Symbol)
Master Symbol Data (Master Symbol)
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,
wild card character
,sequence on No Read,sequence on mismatch>
Default: * (asterisk)
Options: Any 7-bit ASCII character
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card character,
sequence on No Read
,sequence on mismatch>
Default: 1 = Enabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on No Read,
sequence on mismatch
>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K224,
number of master symbols
>
Default: 1
Options: 1 to 10
Serial Cmd: <K225,status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K231,index,master symbol data>
Options: 1 to 32768
Serial Cmd: <K231,index,master symbol data>
Options: Any valid ASCII string