x MS-880 Industrial Long Range Scanner User’s Manual
About This Manual
This manual provides complete information on setting up, installing, and configuring
the MS-880 scanner. The chapters are presented in the order in which a scanner
might be setup and made ready for industrial operation. Host serial commands are
presented side-by-side with ESP and embedded menus.
Chapter 1, “Quick Start” provides overall step-by-step instructions for getting your
scanner operational with specific “go to” references to other chapters and appendices.
Chapter 6, “Autocalibration” explains in detail the autocalibration procedure and the
interpretation of the results.
Chapter 7, “Calibration Database tells how to setup a database of the optical settings
you gathered in autocalibration.
Chapter 8, “Optoelectrics” tells how to setup input/output connections for control of
calibration database settings and includes gain, tracking, and AGC settings.
Chapter 9, “Raster/Laser Control” explains raster and laser setup settings.
Chapter 11, “Matchcode”, Chapter 12, “Outputs”, and Chapter 13, “Output Format
and Filtering” provide instructions for setting up matching labels, data output, and
data formatting for special operations.
Chapter 14, “Discrete I/0” lists input/output functions controlled by discrete electrical
levels, including diagnostic warning outputs setup in Chapter 15, “Diagnostics.
Chapter 16, “Wiring Box Option” describes the wiring box, if used, and it’s installation
and port connections.
Chapter 17, “Utilities” describes ESP-MP utility commands and their related serial com-
mands for read rate tests, defaulting, etc.
The appendices include specifications, reference tables of serial commands, ASCII
characters, multidrop setup and addresses, as well as other useful information relat-
ing to bar coding and electrical and mechanical setups for the scanner.
Host Communications
There are three ways the scanner communicates with a host:
1. Microscan’s Windows™ based ESP-MP™ (Easy Setup Program—Multi-Platform),
the preferred method which offers point-and-click ease of use and visual
responses to user adjustments.
2. Serial commands such as <K100,r1> can be sent from a terminal program. They
can also be sent from the Terminal or Utility window within ESP-MP.
3. Embedded onboard menus are accessed from a terminal window with a <D>
command. These menus lack some of the functionality of the ESP-MP, but may be
more responsive in older, slower computers.