Auxiliary/Configuration System Data
3-14 MS-880 Industrial Long Range Scanner User’s Manual
3–Protocol
Auxiliary/Configuration System Data
Note: Do not use this with Daisy Chain operation.
Auxiliary Status
Note: This command only applies if the Aux Mode is set to Command Processing.
See “Command Processing Mode” on page 2-13.
Configuration Status
When using the 9-pin configuration port it is important to remember to enable this
command.
Definition: When enabled, system data, including decoded data and diagnostic
warning messages, will be routed to the aux port.
Usage: To check label data and error messages via the aux port.
Serial Cmd: <K146,aux status,config status>
Default: Disabled
Options: 0 = Disabled, 1 = Enabled
Definition: When enabled, system data, including decoded data and diagnostic
warning messages, will be routed to the 9-pin configuration port or if
active to the IrDA port.
Usage: To check label data and error messages via the configuration port.
Serial Cmd: <K146,aux status,config status>
Default: Disabled
Options: 0 = Disabled, 1 = Enabled