Chapter 9 Raster/Laser Control
MS-880 Industrial Long Range Scanner User’s Manual 9-7
9–Raster/Laser Con-
Laser Framing Status
To adjust laser framing, click the Raster button, click the Laser Setup tab, and click
the Laser On and Laser Off arrows up or down as shown in figure 9-1.
When Laser Framing is not enabled, the scan beam sweeps across the full scan width.
When enabled, the laser remains OFF during the Laser Off time (see figure 9-2) begin-
ning at the start of the scan beam sweep and turns ON for the duration of the Laser On
Time.
Because scan widths are not always perfectly symmetrical, the most effective way to
setup laser framing is to experiment with the Laser On and Laser Off commands until
you get the best results.
Definition: Sets the length of time the laser is ON during each scan so that only a
selected portion of the scan width is effectively scanned.
Usage: This is useful to avoid highly reflective objects, for filtering out unwanted
signals and avoiding the wrong symbols.
Serial Cmd: <K700,laser on/off status,laser framing status,laser off time,laser on
time,laser power>
Default: Disabled
Options: 0 = Disabled
1 = Enabled
Figure 9-1 ESP Laser
Framing Control
Laser On
Time
Laser Off
Time
Scan beam direction
Figure 9-2 Laser
Framing Pattern
Komentarze do niniejszej Instrukcji