Microscan MS-4X Instrukcja Użytkownika Strona 230

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 312
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 229
Counts
15-12 MS-880 Industrial Long Range Scanner User’s Manual
15–Diagnostics
Counts
(These commands are READ ONLY.)
Powerups
Resets
Definition Returns the number of times the scanner has been re-powered or a
watchdog reset occurs.
Usage: Useful for detecting unwanted resets caused by power supply problems
or ESD transients.
Serial Cmd: Send <K406?>
Returns <K powerups,resets>
Read Only
Ranges:
0 to 65,535 powerups, 0 to 65,535 resets.
Definition Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware
defaults. A watchdog reset is a reset that is forced whenever the soft-
ware locks-up.
Usage: Useful for detecting unwanted resets caused by power supply problems
or ESD transients.
Serial Cmd: Send <K406?>
Returns <K powerups,resets>
Read Only
Ranges:
0 to 65,535 powerups, 0 to 65,535 resets.
Przeglądanie stron 229
1 2 ... 225 226 227 228 229 230 231 232 233 234 235 ... 311 312

Komentarze do niniejszej Instrukcji

Brak uwag