Chapter 11 Matchcode
MS-880 Industrial Long Range Scanner User’s Manual 11-13
11–Matchcode
Caution: Since the total number of characters available for the master label data
base is2710 changes to the Master Label Data Base Size will re-allocate the num-
ber of characters available for each master label and could cause existing master
labels to be deleted (except master label #1 unless it also exceeds the size limita-
tion).
The table below specifies the maximum number of characters available to each label
according to the number of master labels defined, from 1 through 10. See “Master
Label Database Size” on page 11-11.
Table 11-1 Maximum Characters for Master Label Database
Request Master Label Data
Request All Master Label Data
Master Label
Number
Maximum
Characters
Master Label
Number
Maximum
Characters
#1 2710 #6 451
#2 1355 #7 387
#3 903 #8 338
#4 677 #9 301
#5 542 #10 271
Serial Cmd: <K231,master label number?>
This will display data in the master label number you indicated. For
example, to request master label #5, enter <K231,?>. The scanner
transmits master label #5 data in brackets in the following format:
<K231,5/.....>. If no master label data available, the output will be:
<K231,5,>.
ESP: Double-clicking the Master Database tab, as shown under “Enter Mas-
ter Label Data” on page 11-12, will display current master label data for
all master labels.
Serial Cmd: <K231,?>
This command will return master label data for all labels enabled (up to 10).
ESP: Double-clicking the Master Database tab, as shown under “Enter Mas-
ter Label Data” on page 11-12, will display current master label data for
all master labels.