Daisy Chain Autoconfigure
2-16 MS-880 Industrial Long Range Scanner User’s Manual
2–Communications
Daisy Chain Autoconfigure
Note: All slave scanners must be set to Serial for Daisy Chain to function.
See “Trigger Mode” on page 4-4.
When setting up a daisy chain operation, do the following:
1. Set the master (the scanner connected to the host) scanner to Serial.
This sets all the scanners in the daisy chain to Serial when the command is car-
ried out.
2. Send <K150DAISY> command.
3. If necessary, set the master scanner to Edge.
Definition: Daisy Chain Autoconfigure is issued to the master scanner in the
daisy chain and the software responds as follows:
Counts the number of slave scanners in the daisy chain.
Assigns an internal ID number (1...n) to each slave scanner, where
the first slave scanner is number 1 (and its own ID being a 0).
Propagates the communications settings and the relevant operating
modes of the master scanner to the host and auxiliary ports of each
slave scanner.
Resets each slave scanner.
Verifies that each slave scanner has acquired the new settings.
Usage: For quick setup and configuration of the daisy chain network.
Serial Cmd: <K150DAISY>
Before Autoconfigure you must set the master scanner to Serial (S):
SS S
Host
Master
Scanner
Slave
Scanner
Slave
Scanner
After Autoconfigure you may set the master scanner to Edge (E)
but the other scanners must remain in Serial (S):
ES S
Host
Slave
Scanner
Slave
Scanner
Master
Scanner