Noread Message
12-4 MS-880 Industrial Long Range Scanner User’s Manual
12–Outputs
Noread Message
Noread Status
Noread Message
Note: Noread Message will only be transmitted if Bar Code Output (page 12-5) is
set to Match, Mismatch or Good Read.
Noread Message can be set to any ASCII characters except NULL <> and ,
(comma).
Definition: When enabled, and if no bar code label has been decoded before time-
out or the end of the read cycle, the noread message will be transmit-
ted to the host.
Usage: Used in applications where the host needs serial verification that a label
has not been read and especially useful in new print verification.
Serial Cmd: <K714,status,message>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Any combination of ASCII characters can be defined as the noread
message.
Serial Cmd: <K714,status,message>
Default: NOREAD
Options: 0 to 128 ASCII characters.