Chapter 8 Optoelectrics
MS-880 Industrial Long Range Scanner User’s Manual 8-9
8–Optoelectrics
Control Trigger #1
Control Trigger #2
Control Trigger #3
Definition: When Control Trigger mode is enabled, Control Trigger #1 “hijacks”
Input 1 (see “Discrete I/0” in chapter 14) and uses it to select an opto-
electric configuration from the configuration database. Active state is
set by Input 1 serial command.
Serial Cmd: <K226,mode,# active database settings,latch on trigger,timer value,
control trigger 1,control trigger 2,control trigger 3>
Default: Disabled
Options: 0 = Disabled
1 = Enabled
Definition: New Master Pin is used for Control Trigger #2. When enabled and
Mode is set to Control Trigger, this input is used to select a Opto-
electric configuration from Configuration Database. Active State is
“Active Closed”.
Serial Cmd: <K226,mode,# active database settings,latch on trigger,timer value,
control trigger 1,control trigger 2,control trigger 3>
Default: Disabled
Options: 0 = Disabled
1 = Enabled
Definition: Trigger is used for Control Trigger #3, and when enabled and mode
is set to Control Trigger, this input is used to select a Optoelectric
configuration from the Configuration Database. The active state is
set by the External Trigger State serial command.
Serial Cmd: <K226,mode,# active database settings,latch on trigger,timer value,
control trigger 1,control trigger 2,control trigger 3>
Default: Disabled
Options: 0 = Disabled
1 = Enabled