Trigger Filter Duration
Good Decode Reads
Note: When setting up, be sure to determine if the scanner’s scan rate is capable of
scanning your longest label the required number of times.
Definition: Trigger Filter Duration can prevent trigger bounce from falsely trig-
gering the scanner by limiting the time in which trigger pulses can be
received.
Usage: Trigger Filter Duration is useful where trigger bounce could cause
false triggers.
Serial Cmd: <K200,trigger mode,trigger filter duration>
Default: 320 (x 31.25µs = 10ms)
Options: 0 to 65535 (corresponding to 0 to 2.048s in 31.25µs steps)
Definition: The number of decodes (from 1 to 31) required per label before a
label’s decoded data is sent. It requires the scanner to successfully
decode a label a designated number of times (not necessarily consecu-
tively) before it is sent. If it doesn’t achieve the number of good reads
during the read cycle, then a noread will be sent.
Note: Higher settings will decrease throughput speed.
Usage: This is a very useful feature to increase reliability of reads for symbolo-
gies that do not have internal error checking such as Pharmacode.
Serial Cmd: <K221,decodes before output>
Default: 1
Options: 1 to 31