Calibration Database by Serial Command
7-4 MS-880 Industrial Long Range Scanner User’s Manual
7–Calibration Data-
Calibration Database by Serial Command
Note: The Configuration Database is best developed from the ESP Calibration menu.
Database Index
Focus Position
Gain
Tra ck in g
Definition: Stores up to 7 user defined database records that can be entered or set
from autocalibration and retrieved dynamically. See "Overview of Opto-
electrics" on page 8-4 for instructions on setting up the database.
Serial Cmd: <K227,database index,focus position,gain,tracking>
Options: 1 to 7
Definition: Associates a specific focus position with a database index.
Serial Cmd: <K227,database index,focus position,gain,tracking>
Options: 0 to 40
Definition: Associates a specific gain setting with a database index.
Serial Cmd: <K227,database index,focus position,gain,tracking>
Options: 0 to 255
Definition: Associates a specific tracking setting with a database index.
Serial Cmd: <K227,database index,focus position,gain,tracking>
Options: 0 to 127