
Overview of Calibration Database
7-2 MS-880 Industrial Long Range Scanner User’s Manual
7–Calibration Data-
Overview of Calibration Database
Indexes of optical settings can be entered either as individual optical settings or as a
index of settings obtained from the autocalibration procedure. They can be entered in
three ways:
• by ESP in the calibration database menu
•by serial commands
• by Embedded menu commands
Calibration with Multilabel
With Multilabel enabled for more than one label, the scanner may not locate labels at
varying ranges. The reason for this is that once a label is located from the optical
database, the scanner will continue to search for labels that meet that index of focus,
tracking, and gain settings.
Definition: The configuration database allows the user to save up to seven optical-
electrical settings. The database can be used simply to save most com-
monly used settings to make the scanner easily adaptable to changing
applications.
Usage: Useful in applications where a variety of optical-electrical settings are
required to read and decode more than one label type, position, etc.
Serial Cmd: <K227,database index,focus position,gain,tracking>
Komentarze do niniejszej Instrukcji