Defaulting/Saving/Initializing
MS-880 Industrial Long Range Scanner User’s Manual A-27
Appendices
Initializing
Initializing is a part of all save and default functions. It is also used as a follow-on to
implement serial configuration commands into active memory.
• Initializes serial configuration commands in
active memory and resets counters to zero.
• Does not save settings to NOVRAM.
By Serial Command
Send <A> after a serial configuration command or
a string of serial configuration commands, for
example, <K141,1><A>.
By ESP
Right-click in the configuration window and select Save to Scanner, Send No Save.
This will initialize all serial configuration changes that have been made in the current
ESP session.
Loss of Communications
Making changes to communications with the host such as Baud Rate, Parity, Stop
Bits, LRC, etc. without corresponding changes in linked device(s) can result in the
loss of menu access through the 25-pin port and wiring box connections. If this should
occur, connect the scanner to the 9-pin port and set your host communications set-
tings as follows: 57.6K
baud, 8 Data Bits, 1 Stop Bits, and None Parity. These set-
tings for this port are fixed and cannot be changed.you should restore the scanner’s
defaults. If you wish to return to the 25-pin host port, you’ll first need to change the
scanner’s communications settings by sending: <K100,4,1,0,0><Z>.