Counters
17-6 MS-880 Industrial Long Range Scanner User’s Manual
17–Utilities
Counters
Counter commands can be a numeric value from 00000 to 65,535. After reaching the
maximum numeric limit of 65,535, an error message will be displayed and the counter
will automatically roll-over and start counting again at 00000. To obtain the cumula-
tive total of counts after the roll-over has occurred, add 65,536 per each roll-over
(the scanner does not keep track of the number of roll-overs) to the current count.
Note: All counter values will be lost if power is recycled to the scanner or the scanner
receives a reset or save command.
By ESP
You can access Counters from the Utilities menu.
Right-click the appropriate counter option and select Request to display count or
Clear to set counter to zero.
By Serial Command
Noread Counter
Sending <N> displays the total number of noreads that have occurred since the last
reset.
Noread Counter Reset
Sending <O> sets Noread Counter to 00000.
Trigger Counter
Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset
Sending <U> sets the trigger counter to 00000.
Good Read/Match Counter (or Good Read Counter)
Sending <V> displays the total number of good reads matching the master label or, if
Master Label is not enabled, the number of good reads since the last reset. This
counter is always enabled, but will only work as a match count when Master Label is
enabled. If Master Label is not enabled, this counter records the number of good
reads. This count can be requested at any time.