Chapter 4 Read Cycle/Trigger
MS-880 Industrial Long Range Scanner User’s Manual 4-13
4–Read Cycle/Trig-
End of Read Cycle
End of Read Cycle Status
Note: When operating in Continuous Read or Continuous Read 1 Output, the
scanner is always in the read cycle.
Definition: The read cycle is the time during which the scanner will attempt to read
and decode a bar code symbol.
Serial Cmd: <K220,end of read cycle status,timeout>
Definition: A read cycle can be terminated by a new trigger, a timeout, or a combi-
nation of both.
ESP: Double-click on End of Read Cycle Mode and make a selection.
Serial Cmd: <K220, end of read cycle status,timeout>
Default: Timeout
Options: 0 = Timeout
1 = New Trigger
2 = Timeout & New Trigger